5.6 : Lighting




5.6.4 2010 Total Lighting Technology Electricity Consumption, by Sector (TWh per Year) (1)
Residential Commercial Industrial Other (2) Total
Incandescent 136 78% 15 4% 0 0% 4 4% 156 22%
General (A-type, Decorative) 112 64% 9 3% 0 0% - - 122 17%
Reflector 19 11% 5 2% 0 0% - - 24 3%
Miscellaneous 5 3% 0 0% 0 0% 4 4% 9 1%
Halogen 12 7% 15 4% 0 0% 1 1% 28 4%
General  1 1% 0 0% 0 0% - - 1 0%
Reflector 8 5% 7 2% 0 0% - - 15 2%
Low Voltage Display 1 0% 7 2% - - - - 8 1%
Miscellaneous 2 1% 1 0% 0 0% 1 1% 4 1%
Compact Fluorescent 15 9% 16 5% 0 0% 1 1% 32 5%
General (Screw, Pin) 13 7% 13 4% 0 0% - - 26 4%
Reflector 1 1% 3 1% 0 0% - - 4 1%
Miscellaneous 1 1% - - 0 0% 1 1% 2 0%
Linear Fluorescent 10 6% 250 72% 23 40% 10 9% 294 42%
T5 0 0% 16 5% 2 4% - - 19 3%
T8 1 1% 124 35% 12 21% - - 137 20%
T12 7 4% 109 31% 9 15% - - 124 18%
Miscellaneous 2 1% 2 0% 0 0% 10 9% 14 2%
High Intensity Discharge 0 0% 49 14% 35 60% 98 83% 183 26%
Mercury Vapor 0 0% 1 0% 4 7% 4 3% 9 1%
Metal Halide 0 0% 43 12% 25 42% 29 25% 97 14%
High Pressure Sodium 0 0% 5 1% 6 11% 65 55% 76 11%
Low Pressure Sodium 0 0% 0 0% 0 0% 1 1% 1 0%
Other 1 1% 3 1% 0 0% 3 3% 8 1%
LED 0 0% 3 1% 0 0% 2 1% 5 1%
Miscellaneous 1 1% 0 0% - - 1 1% 3 0%
Total 175 100% 349 100% 58 100% 118 100% 700 100%
Note(s): 1) Lumens-hour is a measure of lighting output; Watt-hour is a measure of electrical input for lighting. A value of zero indicates less than 0.5 billion kWh/year. 2) Accounts for the remainder of lamps not installed inside buildings, including parking lot, stadium, stationary aviation, billboard, and traffic and street lighting.









DOWNLOAD TABLE AS PDF XLS


Related Tables:

PDFXLS



PDFXLS



PDFXLS



PDFXLS



PDFXLS





Sources: